Littelfuse products are not designed for, and shall not be used for, any purpose (including, without limitation, automotive, military, aerospace, medical, life-saving, life-sustaining or nuclear facility applications, devices intended for surgical implant into the body, or any other application in which the failure or lack of desired operation of the product may result in personal injury, death, or property damage) other than those expressly set forth in applicable Littelfuse product documentation. Warranties granted by Littelfuse shall be deemed void for products used for any purpose not expressly set forth in applicable Littelfuse documentation. Littelfuse shall not be liable for any claims or damages arising out of products used in applications not expressly intended by Littelfuse as set forth in applicable Littelfuse documentation. The sale and use of Littelfuse products is subject to Littelfuse Terms and Conditions of Sale, unless otherwise agreed by Littelfuse. "Littelfuse" includes Littelfuse, Inc., and all of its affiliate entities.

The 201-SP (201-xxx-SP) series is an 8-pin octal base, plug-in voltage monitor designed to protect single-phase motors regardless of their size. The 201-100-SP is used on 95–120 V ac, 50/60 Hz motors to prevent damage caused by low voltage. The 201-200-SP is used on 190–240 V ac, 50/60 Hz motors. The 201-200-SP-T-9 is a pin-for-pin replacement for a Time Mark® #260 series voltage monitor. High voltage protection is included in the 201-200-SP-T-9.

The unique microcontroller-based voltage and voltage-sensing circuit constantly monitors the voltage to detect harmful power line conditions. When a harmful condition is detected, the MotorSaver’s output relay is deactivated after a specified trip delay. The output relay reactivates after power line conditions return to an acceptable level and a specified amount of time has elapsed (restart delay). The trip delay prevents nuisance tripping due to rapidly fluctuating power line conditions.

Notes:
Must use Model OT08PC socket for UL Rating.
Manufacturer’s recommended screw terminal torque for the RB series and OT series octal sockets is 12 in.-lbs.

Features

  • Proprietary microcontroller-based circuitry
  • Fixed trip delay 4 seconds
  • Advanced LED diagnostics
  • Compact design for 8-pin, DIN-rail or surface mounted

Access specifications, certifications, check availability and order parts below

Catalog #Input
Voltage (V)
Output
Form
Termination TypeMounting MethodDimensionsWeight (lbs/g)HumidityInput AC Line Frequency (Hz)Maximum Input PowerOutput Load Rating (VA)Overvoltage Reset Voltage (%)Overvoltage Trip Voltage (%)Restart Delay RangeStorage Temperature (F/C)Trip Delay RangeStockSamplesCompare
201-100-SP95 - 120 VacSPDTTorque: 12 in-lbs.; 12 - 22 AWG solid or strandedDIN rail or surface mount (plug into OT08-PC socket)1.75 H x 2.38 W x 4.13 D in. (44.5 x 60.3 x 104.8 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacAfter a Fault or Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)Under Voltage Fault: 4 sCheckOrder
201-200-SP190 - 240 VacSPDTTorque: 12 in-lbs.; 12 - 22 AWG solid or strandedDIN rail or surface mount (plug into OT08-PC socket)1.75 H x 2.38 W x 4.13 D in. (44.5 x 60.3 x 104.8 mm)0 Kg10 - 95% non-condensing per IEC 68-2-350 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 VacAfter a Fault or Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)Under Voltage Fault: 4 sCheckOrder
201-200-SP-T-9190 - 240 VacSPDTTorque: 12 in-lbs.; 12 - 22 AWG solid or strandedDIN rail or surface mount (plug into OT08-PC socket)1.75 H x 2.38 W x 4.13 D in. (44.5 x 60.3 x 104.8 mm)0 Kg50 / 60 (50 will increase all delay timers by 20%)5Pilot Duty: 480 VA @ 240 Vac; General Purpose: 10 A @ 240 Vac107%110%After a Fault or Complete Power Loss: 2 s-40° to 80°C (-40° to 176°F)Under/Over Voltage: 4 sCheckOrder